Tablets & Capsules March 2016 29 The inaccuracy of common tests Many different instruments can characterize or predict flow behavior, but most are fairly expensive—between $50,000 and $100,000—and some companies are reluctant to make that capital expenditure. Instead, they opt for inex- pensive flow tests that aren't up to the task. The most common test is tapped density—described in USP General Chapter <616> and in ASTM D7481-09— which assesses the compressibility of a powder. To begin, a specified quantity of powder is placed in a cylinder of known volume. Next, a mechanical device repeatedly taps the cylinder, causing the powder to settle. Once the speci- fied number of taps is delivered, you compare the settled volume to the original freely settled volume. The Hausner Ratio is correlated to the flowability of a powder or granular material. It is calculated by the formula H = where ρT is the tapped bulk density of the powder and ρB is the freely settled bulk density of the powder. A Hausner Ratio greater than 1.25 is said to indicate poor flowability. But the Hausner Ratio is not an absolute property of a material; its value can vary depending on the methodology used to determine it. Nonetheless, it is used in a variety of industries to indicate powder flowability. The Carr Index is also said to measure flowability and, like the Hausner Ratio, it uses the difference in the tapped and loose densities. It can be expressed as C = 100 x (1- ) where ρB is the freely settled bulk density of the powder and ρT is the tapped bulk density of the powder. A Carr Index greater than 25 is said to indicate poor flowability, and a value of 15 or less indicates good flowa- bility. The Hausner Ratio and the Carr Index are sometimes criticized—despite their relationships to flowability being established empirically—as not having a strong theoretical basis. Use of them persists, however, because the equip- ment required to perform the analysis is relatively cheap and the technique is easy to learn. Another simple but flawed test measures angle of repose. For this test, you pour the powder onto a flat surface and then measure the slope (angle) of the powder relative to the horizontal. The higher the angle, it's said, the more difficult it is for the material to flow. The problem with this test: It relies on human judgement and is thus prone to inaccuracy; many plant managers refuse to rely on it. A better approach is to measure bulk density using a shear-cell-based instrument, as shown in the photo above and on page 27 [1]. Not only does a shear cell supply pre- cise bulk density information, it measures important flow metrics that characterize bulk solids behavior, such as flow function, arching dimension and rat-hole diameter. Flow characterization using a shear cell The annular shear cell, developed in the 1960s, imparts a shearing action to a powder sample in order to evaluate the amount of force needed to overcome inter-particle friction. It allows shear data to be rapidly collected on bulk solids. This, in turn, allows quick analysis and timely QA/QC checks of powders used to make tablets and other products. The shear cell simulates the conditions in a bin that affect the flow of material through the orifice of a hopper using two components: a shear cell lid and a trough. It does so by applying a series of defined compressive loads on a small sample of powder and then shearing the particles in the lid against the particles in the trough. This measures the inter-particle friction of the material and creates a predictive flow model of powder moving through a gravity discharge system. It's then possible to quickly derive flow function data. As increasingly compressive loads are applied to the small sample of powder, bulk density measurements are taken. The beauty of the shear cell is its operational simplicity and robust data output. Information from one flow func- tion test provides enough data to calculate a flow function curve, arching dimension, final bulk density, rat-hole diameter, and internal friction angle. The shear cell also performs a stand-alone bulk density test that you can run in as little as 100 seconds. The test can be used to characterize the bulk density of the mater- ial and to quickly and accurately check quality. ρT ρB ρB ρT Powder flow tester

Articles in this issue

Archives of this issue

view archives of Tablets & Capsules - TC0316