Tablets & Capsules

TC0516

Issue link: http://www.e-digitaleditions.com/i/678483

Contents of this Issue

Navigation

Page 32 of 53

Tablets & Capsules May 2016 31 lating ODMTs because tablet strength is directly related to the compaction force used. As a result, an accurate quantity of disintegrant must be added to promote rapid disintegration in the buccal cavity, where there is little moisture. The range of acceptable friability was set between 0.1 and 0.9 percent weight loss based on our experience with orally disintegrating products. All the ODMTs made at pressures ranging between 130 and 350 MPa met the friability requirement. This pressure range was selected because it corresponded to the most favor- able region from the plots of TTFS and compaction pres- sure shown in Figure 5. Disintegration test. The disintegration test was per- formed using a PZT-S tester (PharmaTest, Hainburg, Germany). The tablets were placed in vials, and the disin- tegration bath was filled with 800 milliliters of water. The temperature was regulated using two thermometers to ensure that the tablets were tested at the optimal temper- ature of 37° to 38°C. By definition, orally disintegrating tablets must disin- tegrate within 30 seconds. For this test, three tablets made at each of the eight compaction forces (24 tablets total) were tested and the results averaged. See Table 2. As shown in Figure 7, the ODMTs made at compaction pressures exceeding 278 MPa did not meet the 30-second standard. TTFS. The TTFS of the ODMTs was measured using the tablet tensile analyzer described above. It includes multiple interconnected components, including a top- loading balance, digital micrometer, and a sensitive load cell. The TTFS system automatically measures and records the final weight, thickness, and diameter of each tablet before measuring tensile fracture stress. Figure 8 shows the TTFS measurements for each tablet made at 75-, 150-, and 250-kilogram (kg) loads. Note the differ- ence in results when the analyzer used a 10-kg load cell instead of a 500-kg load cell, which is less sensitive. In operation, the analyzer measures tablet diameter first, detects the force required to break the tablet, and then immediately stops measuring and returns to the start position. Because this method records the tablet's force- displacement profile during fracture and records the load at the point of fracture, it gives more accurate results than less sensitive analyzers that operate at higher speed. They tend to overstate the fracture load and provide no infor- mation about the force-displacement profile. As shown earlier in Figure 5, the ODMTs must be made at a compaction pressure of approximately 1 MPa in order to meet the minimum hardness requirement. But identifying the optimal compaction pressure requires Table 2 Disintegration time of ODMTs Compaction Disintegration Average pressure times of 3 disintegration (MPa) tablets (s) time (s) 35 4, 4, 5 4.33 69 5, 5, 5 5 104 5, 5, 4 4.67 139 5, 6, 5 5.33 208 9, 11, 11 10.33 278 17, 17, 16 16.67 346 38, 39, 39 38.67 416 47, 48, 48 47.67 Figure 7 Disintegration time plot 50 45 40 35 30 25 20 15 10 5 0 Disintegration time (s) Compaction pressure (MPa) Acceptable range for ODMTs 0 50 100 150 200 250 300 350 400 450 Disintegration time Table 1 Friability of ODMTs Compaction Initial weight Final weight Weight loss Weight loss pressure (mg, average (mg, average (mg) (%) (MPa) of 7 tablets) of 7 tablets) 139 175.10 173.97 1.13 0.645 208 175.90 174.90 1.00 0.569 278 174.70 173.90 0.80 0.458 345 176.50 175.70 0.80 0.453 Figure 6 Percentage weight loss from ODMTs after friability testing 0.7 0.65 0.6 0.55 0.5 0.45 0.4 Weight loss (%) Compaction pressure (MPa) 100.00 150.00 200.00 250.00 300.00 350.00 400.00 450.00

Articles in this issue

Archives of this issue

view archives of Tablets & Capsules - TC0516