ICT Today

ICT Today October/November/December 2020

Issue link: https://www.e-digitaleditions.com/i/1284149

Contents of this Issue

Navigation

Page 41 of 79

42 I ICT TODAY The use of fences, trenches, berms or other manmade or earthworks to create a perimeter or barrier around the EDC site can further prevent access by unauthorized indi- viduals. Air conditioning condensing units, generators or other auxiliary equipment should also be placed within these barriers. Depending on location, no trespassing and limited access signage is recommended to indicate private property. Signage that highlights any potential risks from exposures to electricity, light and radio waves and pro- vides contact information for site owners, administrators or management is also recommended. THERMAL MANAGEMENT WITHIN THE EDGE Heat that is externally present or generated internally by the device and not adequately removed is detrimental to the performance and reliability of a communication and computational electronic circuit. That is why ther- mal management is one of the core subjects of any tradi- tional data center infrastructure and critical to protecting active equipment. Physically locating IT and cloud-based services closer to end users and devices as described in the EDC concept means that a high-capacity, data center-like environment will often be required in public locations, such as office buildings, shopping centers, school campuses, event are- nas and wireless cell sites. There are several considerations when planning a cooling solution for an EDC that will maximize compute, caching and networking performance, including cost as it may not justify the benefit of an EDC or may not be physically feasible. Therefore, thermal management of an EDC must be considered for each level of cooling and heating, including: • Component Level: The component is the base of the heat source. It often relies on conduction to a case mounted heatsink and printed circuit board (PCB). • Equipment (chassis, blade) Level: The equipment must be designed to effectively remove heat from the component. It often relies on fans and air to remove the heat directly from heatsinks and PCBs and, therefore, indirectly from the components. • Rack/Cabinet/Container Level: Plan equipment layout to provide a thermal path for removing heat from the equipment according to the thermal management design of the floor (e.g., equipment stacking arrangement, heat baffle, thermal duct, fans, liquid bath). • Floor Level: Plan the floor to maximize the perfor- mance of thermal management while minimizing the cost. • Overall Environment: Consideration of tempera- ture and humidity in and around the environment should also be considered. Considerations for the thermal management of data storage and transport equipment includes the methods and systems sufficient to maintain the equipment operat- ing environment (temperature and humidity) within the physical operating condition range. Unless equipment has requirements stating otherwise, EDC equipment with sup- ply air should be controlled to meet ASHRAE TC9.9 guide- lines, which include one recommended and four allow- able ranges (A1 to A4). ASHRAE's recommended range for all equipment is 18°C to 27°C (64.4°F to 80.6°F). Allow- able ranges A1 to A4 as compared to the recommended range can enable potential cost savings for environments, most notably those relying on the free cooling technolo- gies. Typically, these environments will operate at upper ASHRAE limits, reducing cooling need and expense. Server, storage, and switch gear power levels are on the rise, thereby driving higher power dissipation in racks and making cooling more of a challenge.

Articles in this issue

Archives of this issue

view archives of ICT Today - ICT Today October/November/December 2020