Pharmaceutical Technology - March 2022

Pharmaceutical Technology March 2022

Issue link: https://www.e-digitaleditions.com/i/1462155

Contents of this Issue

Navigation

Page 12 of 54

Pharmaceutical Technology QUALITY AND REGULATORY SOURCEBOOK EBOOK MARCH 2022 13 A thorough understanding of regulatory author- ity expectations is essential to minimizing the risks for marketing authorizations. Impacts to sponsors of regulatory deficiencies and 483 observations Method validation deficiencies can have a significant impact on the approval of combination products. At a minimum, there will be significant costs associated with addressing any deficiencies and observations. Areas of a combination product submission that may be impacted due to improper method validation are as follows: • Method validation: Deficiencies in validations will likely require a company to perform some re-validation of the impacted methods. For ex- ample, if an appropriate sample concentration range was not validated, the method will need to be re-validated to cover the appropriate sample concentrations. In addition, while not common, re-validation of a method can uncover deficien- cies in the method that, when addressed, calls into question all areas of the submission where data from that method is used, such as for stabil- ity and product expiration dating. • Verification and validation studies: Device ver- ification and validation studies should always be conducted with fully validated methods. Given the complexity of combination products, the ab- sence of proper oversight could lead to methods being overlooked in terms of criticality for verifi- cation studies. Additionally, if methods are not appropriately validated and it is determined that the original method was not adequate to support device design specifications, the verification and validation studies may need to be repeated or ap- pended once the methods are fully validated. • Pre-clinical biocompatibility: Improper method validation of methods used for pre-clin- ical biocompatibility may require the complete repeat of the biocompatibility studies. Given the considerable time and costs of biocompatibility, the risks to the overall program are substantial. It is critical during this phase of development that all methods used properly consider drug/bi- ologic and device interaction, and all studies should use proper controls. If biocompatibility is outsourced, thorough auditing of vendor meth- ods is strongly encouraged. • Finished product stability studies: Method val- idations can have a significant impact on combi- nation product stability studies. If re-validation identifies method insufficiency, the stability data may be called into question. Having to repeat long-term stability and the associated manufac- turing and testing adds significant costs and time (possibly more than a year) to product ap- proval timelines. • Complete response letter: Observations related to method validation can and have resulted in a complete response letter from FDA. This will re- sult in a delay in approval ranging from one month to years, depending on the severity of the overall deficiencies identified in the application. • Repeat of clinical studies: Although unlikely, improperly validated methods could ultimately result in requirements to repeat clinical trials. An inability to demonstrate that design specifi- cations are in control due to methods not being suitable for use could ultimately have clinical implications if the verification/validation and pre-clinical studies need to be repeated. Because test methods are so integral to all areas of combination product marketing applications, related

Articles in this issue

Archives of this issue

view archives of Pharmaceutical Technology - March 2022 - Pharmaceutical Technology March 2022