Capsules are fairly easy to fill, but sometimes things go wrong. Here are some tips on how to stop defects. First, before filling the machine's hopper with empty capsules, verify that the capsules meet your dimen- sional specifications by checking a representative sample. Even capsules from the most reputable manufactur- ers may differ slightly. The same is true of tooling supplied by different vendors, so be prepared to make some adjustments. Of course, verify your settings and check that routine maintenance has been performed before you start. And be sure you understand how the active ingredient and/or formulation can affect filling. Next, check the environmental conditions within filling room. Ideal conditions are a temperature of 22°C ±2° and a relative humidity of 40 to 50 percent. If conditions are outside these ranges, allow some time for the room and the materials within it acclimate before you begin produc- tion. If defects occur, try resolving the problem using one or more of these troubleshooting tips. Lumpy or misshaped capsules. If the capsules form lumps or are other- wise misshaped, check the conditions under which they were transported or stored. Empty capsules should be maintained at a temperature between 15° and 30°C and a relative humidity between 40 and 65 percent. Avoid exposing empty capsules to a direct source of light or to heat. Do not transfer capsules suddenly from a high-temperature environment to a low-temperature one. Improper rectification. If the cap- sules are not being oriented properly (cap up), first make sure no one is using a plastic container to transport the capsules or a plastic scoop to load the capsule filler. Plastic can cause an electrostatic charge to develop, hin- dering rectification. Use stainless steel containers and scoops instead. Also check the gate knee and adjust it as necessary. Verify that the stroke of the pushers, or fingers, is set properly according to the joined length of the shells. Also check that the raceway is in good condition. Failure to separate. If the caps and bodies fail to separate, check the the vacuum. On most capsule fillers, the gauge should read somewhere between 15 and 18 inches mercury. You many also need to adjust the gap between the machine's cap segments and body segments. Check the tim- ing of the solenoid valve and how well the segments' holes align with the raceway fingers. Check the filter bag and clean it periodically. Dented capsules. Dents can form on the dome of the cap and/or body for a variety of reasons. One cause is improper setup that leads to the machine applying excessive pressure. To determine the correct setting, manually lock 20 capsules together and measure their length. Next, find the mean value and adjust the machine to that value with the help of a tie rod. Another reason for dented capsules is overfilling. To correct this, weigh 20 filled capsules. The average weight should not exceed the specified volume of the capsules you're using. If it does, con- sider using larger capsules. Telescoping. This defect occurs when the cap and body misalign and the capsule body splits and a portion of it covers the cap. To eliminate this defect, make sure all the capsules are perfectly round. Also check the alignment of the cap and body bush- ings, or segments, using a gauge designed for that purpose. The envi- ronmental conditions in the filling room can also contribute to this problem. If the machine must be stopped for more than 30 minutes, protect the capsule shells from direct exposure to the environment. Popping. If the capsules open or elongate after filling, it's likely due to excessive locking pressure or overfill- ing. It's also possible that the locking mechanism is weak, but that's a defect rarely seen in capsules sup- plied by reputable manufacturers. Brittleness. Check your storage conditions. When capsules lose mois- ture, often due to poor storage prac- tices, they become brittle. The thresh- old is approximately 12.5 percent moisture. Anything less will likely lead to brittleness. Filled capsules that include a hygroscopic active or excip- ient can also cause brittleness. Capsules made from HPMC are less likely to become brittle. T&C Kaushal Kumar, PhD, is head of technical services at AlfaCaps, 151 1st Avenue, Suite 115, New York, NY10003. Tel. 866 250 8409. Website: www.alfacaps.com b a c k p a g e Troubleshooting common capsule defects If the filling machine must be stopped for more than 30 minutes, protect the capsule shells from direct exposure to the environment.

Articles in this issue

Links on this page

Archives of this issue

view archives of Tablets & Capsules - TC0118