January/February 2018 43 focus on these types of buildings. Most of the teams involved know each other and share information on good sources for advice and proven solutions. Commercial real-estate salespeople also are interested in having multiple restaurant-friendly spaces in their community to rent to potential tenants. ey know the value this provides in securing quality tenants for spaces they want to lease. It reduces contingencies and deal-killing clauses that cannot be satisfi ed. What makes a foodservice-friendly building? Access for grease exhaust duct and fan If direct access to a roof is not possible, then space should be available for an optional scrubber or pollution- control unit. I am aware of several large restaurant lease deals that never closed because the developer didn't off er provisions to install exhaust air fi ltration equipment that would be needed to lease the space to a restaurant. Reasonable headroom e section of the rental space, assumed to be where the kitchen will be located, should have at minimum a 9-foot clearance from the fl oor to the underside of a structure. Codes require an exhaust hood to be hung no lower than 6 feet 8 inches. Assuming it's a 2-foot- high shallow hood, an 8-by-8 minimum is required to install that hood. Add 4 inches for the hardware and lighting that may extend from the top of the hood and 9 feet becomes the minimum.