www . machinerylubrication.com | September - October 2018 | 23 is 77 amps. erefore, if the pressure in the system is 3,000 PSI and the amperage is less than 77 amps, the pump is bypassing. A variable-displacement pump will have a case drain that will keep pressure from building against the shaft seal. Internally bypassed oil returns to the tank through the drain instead of building case pressure. If a variable-displacement pump has excessive case flow, it is worn and must be replaced. Piston pumps normally bypass 1-3 percent of the maximum pump volume, whereas vane pumps can bypass as much as 5 percent. By permanently installing a flow meter in the case drain line, the case flow can be measured regularly. e pump should be changed when the case drain flow reaches 10 percent of the maximum pump volume. A monthly preventive maintenance checklist can tell you at a glance how your pump is doing. How long would it really have taken to make benchmark checks of the current draw and case flow at times when you knew the pump was good? e pump is not the only thing that can bypass and slow down your machine. Almost all your components can bypass. is includes directional valves, cylinders, hydraulic motors, proportional valves, relief valves and other pressure-control valves. When a component bypasses, there will be a pressure drop. As we teach in our classes, any pressure drop that doesn't result in mechanical work will generate heat. An abnormal temperature gain across any component indicates bypassing, but there's no way to know what is abnormal unless you already knew what was normal. us, it behooves you to be familiar with your machines. An infrared temperature gun can be invaluable in learning normal temperature gains and spotting abnormal ones. Making Strange Noises Unusual sounds coming from a hydraulic machine shout imminent failure. If your car started making a funny noise, you would check it out or have it checked immediately, wouldn't you? So why do you allow your expensive hydraulic machines to cry out for help as long as they are still producing? Production will halt before long if certain sounds are not addressed. Aeration and cavitation are common indi- cations of machine failure. Many people don't know the difference between the two, and most will just let them continue until the pump fails and has to be replaced. But if these indicators are caught early, pump failure can be avoided. Cavitation is a steady, high-pitched whining sound. Aeration is much more erratic and is usually accompanied by a sound similar to gravel rattling around inside a pump. Both will destroy the pump if they are not corrected right away. e most common cause of cavitation is a plugged suction strainer or filter. Suction strainers are usually below the level of the oil, out of sight and out of mind. If cavitation is heard, check the strainer. Low oil temperature is the second most common cause of cavitation. Never start the machine with oil colder than 40 degrees F. Also, A suction strainer normally is located below the oil level. An air heat exchanger should be located near a cool air source. WE HAVE A BETTER SOLUTION. 800-435-7003 www.ifhgroup.com