the different options for monitoring
these properties.
Genera l ly, sensors do not
measure and report results like an
oil analysis lab test. Most must be
specified to the fluid they are moni-
toring. is requires comparing the
sensor readings with the normal or
abnormal conditions to be moni-
tored in the oil. Laboratory support
may be needed to correlate the
sensor's electric signal with specific
oil parameters. Finally, remember that
all sensors do not have the same reso-
lution and accuracy, so get to know
your sensor's capabilities, applications
and connectivity possibilities.
By using online sensors, field tests,
inspections and routine oil analysis,
you can detect water contamination
and take corrective action earlier with
relatively low monitoring costs. While
the options are vast, you should be
able to find a strategy that best fits
your budget and reliability goals.
ML
About the Author
A lejandro Meza is a senior
technical consultant with Noria
Corporation. He has more than 20
years of experience in the lubricant
industry, technical services, quality
assurance, training, consulting and
development in the United States,
Brazil, Mexico and the A mer-
icas region. Contact Alejandro at
ameza@noria.com to learn how
Noria can help you identify the best
ways to monitor water contamina-
tion in your lubricants.
Some sensors can measure water
saturation as well as total moisture content.
An online water-in-oil sensor
ML