Issue link: https://www.e-digitaleditions.com/i/1527415
12 OctOber 2024 Inhalation Subvisible particles Microscopy e microscopic particle count test uses a binocu- lar microscope for visual inspection. e liquid sam- ple is first filtered through a membrane filter, either black or dark grey in color with a nominal pore size of 1 µm or finer, and the particulates remaining on the filter are counted. Caution should be exercised to minimize particulate contamination from the envi- ronment and the equipment used, and the assay is preferably conducted in a controlled environment, such as a laminar-flow cabinet. It is one of the two compendial methodologies (the other being light obscuration) for the assessment of subvisible parti- cles with a particle size range of about 10 µm. As this method is laborious with a low throughput, it vation duration and/or a higher intensity might be warranted for more difficult samples, such as colored or turbid preparations or when colored containers are used. is guidance on visual inspection for vis- ible particles originally focused on the detection of particulate contamination of external sources (e.g., packaging), though the significance of the presence or detection of intrinsic particles has been acknowl- edged more recently to account for various emerg- ing biotherapeutics (e.g., cell therapy) [12]. Visual inspection serves as a convenient, straightforward test for monitoring or screening purposes. However, it only yields dichotomous outcomes (i.e., presence or absence). ere is also no clear definition of the size threshold for particles to be considered visi- ble, although size limits of 50 to 500 µm have been reported [11, 13, 14]. Techniques Operating Principle Measurement Size Range Strengths Limitations Visible particles Visual inspection Visualization Presence of particles > 50 µm Easy to perform; compendial Subjective; low resolution Subvisible particles Microscopy Microscopy-assisted visualization Size, morphology and counts > 10 µm Easy to perform; compendial Laborious Light obscuration Light blockage Size and counts 2 – 150 µm Rapid analysis; size-based particle counting; compendial Sensitive to contamination; depends on particle transparency Flow imaging microscopy Microscopy- assisted imaging Size, morphology and concentration 1 – 300 µm Subpopulation characterization Emerging technique Submicronic particles UV absorbance Light absorbance Turbidity > 400 nm Easy to perform Limited information Dynamic light scattering Light scattering Hydrodynamic size 10 – 1,000 nm Non-destructive Low resolution among subpopulations PAGE Gel separation in an electric field Electrophoretic mobility (native-); molecular weight (SDS-) kDa to MDa Separation; analyze native proteins (native); differentiate covalent aggregates (SDS-) Limited quantification capability SEC-HPLC Molecular sieve Hydrodynamic size 1 – 1,000 kDa Well-established; separation; high throughput Matrix interactions possible; often require sample dilution Nanoparticle tracking analysis Light scattering- assisted visualization Hydrodynamic size 20 – 1,000 nm Per particle detection; estimate concentration Emerging technique Mass photometry Light scattering Molecular weight 30 – 5,000 kDa Low sample volume and concentration; rapid analysis; simple sample preparation; per molecule measurement Emerging technique; low sample concentration (100 pM to 100 nM) Table 1 Overview of selected analytical techniques for detecting and characterizing protein aggregates in inhaled protein formulations