Inhalation OctOber 2024 13 obscuration [17]. Like light obscuration, a continu- ous stream of sample passes through a flow cell posi- tioned between a light source and an imaging system, which consists of a magnifying module and a dig- ital camera. Successive bright field images are cap- tured and the particles on these images are analyzed by their number, shape and transparency, using the accompanying software in real time. FIM has a mea- surement size range between 1 and 300 µm. One sig- nificant advantage of FIM over light obscuration is its capacity to distinguish subpopulations of particles since the particulates are visualized and information about their morphology can be obtained. e use of FIM in characterizing inhaled dry powders of mono- clonal antibody prepared by thin-film freeze drying has been reported [18]. Submicronic particles UV spectroscopy Apart from measuring ultraviolet (UV) absorbance at 280 nm, which is frequently used to determine pro- tein concentration, UV absorbance at wavelengths above 320 nm (e.g., 350 nm) can be measured to determine sample turbidity [15]. It detects the pres- ence of particles of hydrodynamic diameter above 400 nm. Since aggregate-free protein solutions do not show absorption above 320 nm, any absorption is attributable to light scattering by the aggregate par- ticles, provided no other components in the sample is mainly reserved for difficult samples, for instance, viscous samples or preparations with reduced clarity. Light obscuration Light obscuration works on the principle of light blockage, which is best suited for the measurement of particles with sizes approximately 2 to 150 µm [3, 15, 16]. During measurement, a dilute stream of par- ticles in a suspension is passed between a laser source and a detector. As the suspended particle in the sam- ple flows through, it obscures the light from reach- ing the detector. e shadow cast can then be used to infer the size of the blocking particles through a calibration curve, whereas the frequency of obscu- ration determines the number of particles according to their sizes present in the sample. is compendial method is considered preferred over the microscopic technique for quantifying subvisible particles. While there are acceptance criteria for the maximum num- ber of particles greater than 10 and 25 µm (no more than 6,000 and 600, respectively, per container with a nominal content of no more than 100 mL), these criteria are only applicable to parenteral preparations. No acceptance criteria have been stated for non- injectable liquid preparations. Flow imaging microscopy Flow imaging microscopy (FIM), also known as micro-flow imaging (MFI), is a particle imaging technique that addresses several limitations of light