Issue link: https://www.e-digitaleditions.com/i/1527415
14 OctOber 2024 Inhalation of the particles. As small particles move more quickly, the scattering pattern fluctuates more rapidly, which is reflected by a faster decay (or decorrelation) in the autocorrelation function. e fundamental size distribution of DLS is based on intensity (or scattered light). It is a sensitive method to detect the presence of a small number of large aggregates because the scattering intensity is approx- imately proportional to the square of the molecular weight or the 6th power of the diameter. Nonetheless, there is a risk of smaller aggregates being masked as a result. DLS has a typical measurement duration of a few minutes. Furthermore, DLS is non- destructive and precious samples can be recovered after measure- ment for other analyses. e required sample volume for modern instrumentation can be as low as tens of microliters, with a wide compatible range of protein concentration. ese features render DLS a popular analytical method for characterizing protein aggre- gates when developing inhalable formulations [8, 13, 14, 24, 25]. SEC-HPLC Size-exclusion chromatography (SEC) or SEC-high performance liquid chromatography (SEC-HPLC) is a well-established technique frequently used for aggregate analysis, separating molecules based on their hydrodynamic size [15, 24-28]. SEC typically consists of a column filled with porous beads of predefined sizes through which samples are eluted. Molecules that are sufficiently small can penetrate through the pores, but the larger aggregates cannot. Since the solvent inside the pores is stagnant, small molecules that have been diffused into the pores are retained and ceased from traveling with the elut- ing mobile phase, resulting in a longer retention time than their larger counterparts. e molecular size range at which the separation is most effective is determined by the pore-size of the packing mate- rials. With optimal column selection, good resolu- tion between monomers and dimers or oligomers can be achieved, making SEC particularly suitable for characterizing small protein aggregates. SEC has an added benefit of detecting protein fragmentation, another possible degradation that can happen during bioprocessing and atomization. Samples eluted from SEC-HPLC are usually detected by UV-visible spectrophotometers, where the absorbance at 280 nm or lower (e.g., 214 nm) is measured for quantification. Other detectors can be utilized, such as the multi-angle light scattering (MALS) detector, which permits the determination of the absolute molecular weight of the eluted mol- ecules over a typical range of 10 3 to 10 7 g/mol. In a MALS detector, a polarized laser beam is emitted through a flow cell where the sample passes through. e lights scattered by the sample are simultaneously detected by multiple detectors positioned at different scattering angles, which are used to infer the absolute absorb light at the same wavelength [19, 20]. e aggregation index, defined as: A 350 ×100 (A 280 - A 350 ) is a simple parameter that can be calculated to eval- uate the state of protein aggregation. A value below 3 indicates the sample is transparent, while a value above 30 suggests the sample is heavily aggregated. UV spectroscopy is a rapid, non-destructive tech- nique that is available in most laboratories. While it does not provide additional information such as aggregate size or morphology, it serves as a good ini- tial screening test for detecting protein aggregation. Native- and SDS-PAGE (polyacrylamide gel electrophoresis) PAGE is a method that separates proteins in the sample mixture by electrophoresis through a polyacrylamide- based gel matrix. When PAGE is run in native condi- tion, the separation of proteins will be determined by both the size and the intrinsic charge (electrophoretic mobility) of the molecules. In SDS-PAGE, the sepa- ration is primarily based on their molecular weight, because the excess amount of SDS (sodium dodecyl sulfate) can mask the intrinsic charge of the protein, rendering all proteins a similar charge/mass ratio. Native-PAGE separates proteins, including aggre- gates, in their native state. With SDS-PAGE, SDS denatures the proteins and disrupts all non- covalent aggregates, conveniently distinguishing covalent aggregates. Furthermore, a reducing condition (e.g., using dithiothreitol, DTT) can be used to cleave aggregates involving disulfide bonds and leaving those formed through non-reducible covalent bonds intact [21, 22]. Upon completion of the electrophoresis, the gel is stained for visualization. Semi-quantification can be achieved by densitometry analysis of the cap- tured images of stained gels. For enhanced quantifica- tion and assay throughput with automation, capillary electrophoresis systems can be used [23]. Dynamic light scattering Dynamic light scattering (DLS), also known as pho- ton correlation spectroscopy (PCS), is a commonly used technique for the measurement of particle size distribution between approximately 10 nm and 1,000 nm, i.e., submicronic particles. DLS measures the hydrodynamic diameter of particles suspended in liquid samples. It works by the principle of light scat- tering. When a monochromatic light passes through the suspension, it is scattered by the particles and the scattered light is detected. Since submicronic parti- cles undergo Brownian motion, the intensity and the pattern of the scattered light fluctuates over time due to varying constructive or destructive interferences. ese temporal fluctuations are analyzed by an auto- correlation function to estimate the size distribution