Inhalation

INH0426

Issue link: https://www.e-digitaleditions.com/i/1544305

Contents of this Issue

Navigation

Page 29 of 47

Understanding microstructure is a significant part of the project development pipeline, from early manufacture of active pharmaceutical ingredients (APIs), formulation development, quality control and bioequivalence testing. Microstructure has strong links to processing and performance. For example, different API manufacturing processes may produce differing amounts of internal porosity [1] and the final porosity of tablets can affect their dissolution behavior [2]. For inhaled products, the microstructure of an emitted aerosol can affect product dissolution and therefore, performance of an inhaled product [3-5]. 28 April 2026 Inhalation Critical insights for product development through 3D X-ray imaging X-ray computed tomography (XCT) can non-destructively provide valuable microstructure information Parmesh Gajjar, PhD a, b, c and Darragh Murnane, PhD a, c a Informix Pharma Limited b University of Manchester c University of Hertfordshire Importance of microstructure Understanding microstructure is a significant part of the project development pipeline, from early manu- facture of active pharmaceutical ingredients (APIs), formulation development, quality control and bio- equivalence testing. Microstructure has strong links to processing and performance. For example, differ- ent API manufacturing processes may produce dif- fering amounts of internal porosity [1] and the final porosity of tablets can affect their dissolution behav- ior [2]. For inhaled products, the microstructure of an emitted aerosol can affect product dissolution and therefore, performance of an inhaled product [3-5]. e aerosol microstructure for dry powder inhalers (DPIs) is intimately related to the interaction and structuring between the API and excipient lactose, which is created during blending. erefore, along with the microstructure of the emitted aerosol, the microstructure of the pre-actuation formulation is also important [6]. Need for a complementary characterization method A number of microstructural characterization meth- ods exist that can be used on pre-actuated formula- tions, including morphologically directed Raman spectroscopy (MDRS) [7], scanning electron micros- copy with energy dispersive X-rays (SEM-EDX) [8] and time-of-flight secondary ion mass spectrometry (ToF-SIMS) [9]. Figure 1 summarizes the attributes of these methods. All of the methods can achieve a resolution below 5 µm needed to resolve the micron- ized API, although MDRS can often struggle with smaller-sized particles due to the 3 µm spot size lim- itation of the incident laser [10]. Notably, all of the methods are surface-level methods [11], which have a depth penetration well below 1 mm, and all of the methods require destructive preparation of the sam- ple and therefore disturb the microstructure [12]. Each of these techniques are valuable in their own right, and each serves a slightly different purpose. For example, Raman spectroscopy is a speciation method, whereas ToF-SIMS provides chemical information at particle surfaces. Nevertheless, a complementary and orthogonal technique is also needed, which can pro- vide information in a non-destructive manner, espe- cially deeper than the surface. X-ray computed tomography: A true 3D technique One technique that has the potential to provide fully 3D, non-destructive details on pre-actuated formula- tions is X-ray computed tomography (XCT), which is also known as X-ray microscopy. It is the sister technique of medical CT and has grown in popular- ity across a diverse array of fields in materials science. Traditionally considered a density and morphology measurement technique, XCT techniques can also utilize diffraction, phase contrast and fluorescence. A previous article in Inhalation by this author [13] gave a detailed explanation of the XCT technique. Briefly, illuminating a sample with X-rays allows a radiographic projection similar to clinical X-ray radiographs, and by rotating the sample, the radio- graphs are taken from multiple angles. e illumi- nating X-rays beam may be produced either from an electron tube, as with laboratory XCT machines, or from synchrotron light, which is a much brighter

Articles in this issue

view archives of Inhalation - INH0426