Photovoltaic System LABELING REQUIREMENTS NEC 2014 ARTICLE 690 AND IFC 2012 Breaker Panel / Pull Boxes Main Service Disconnect Main Service Disconnect 9 10 11 NEC 690.5(C) l Part No. 596-00498 NEC 690.33(E)(2) l Part No. 596-00244 NEC 690.17(E) l Part No. 596-00497 NEC 110.27(C) & OSHA 1910.145(f)(7) Part No. 596-00499 Labeling Requirements for Article 690 NEC 690.13(B) Each photovoltaic system disconnecting means shall be permanently marked to identify it as a photovoltaic system disconnect. NEC 690.15, IFC 605.11.3 If the equipment is energized from more than one source, the disconnecting means must be grouped and identified. NEC 690.16(B) Non-load break rated disconnect means shall be marked. NEC 690.17(E) Where all terminals of the disconnecting means may be energized in the open position, a warning label shall be mounted on or adjacent to the disconnecting means. NEC 690.31(B) Identification and Grouping Photovoltaic system conductors shall be identified and grouped. The means of identification shall be permitted by separate color coding, marking tape, tagging or other approved means. NEC 690.31(G)(3)(4), IFC 605.11.1.2 Labels shall appear at every section of the wiring system that is separated by enclosures, walls, partitions, ceilings or floors. Spacing between labels not to exceed 10 feet (3 m). NEC 690.33(E)(2) Interruption Current: be a type that requires the use of a tool to open will be marked "Do Not Disconnect Under Load." NEC 690.35(F) A PV power source shall be labeled at each junction box, combiner box or disconnect, and device where energized, ungrounded circuits may be exposed during service. NEC 690.31(G)(1) Where circuits are embedded in build up, laminate or membrane roofing materials not covered by PV modules and associated equipment, the location of the circuits shall be clearly marked. NEC 690.31(I) Bipolar photovoltaic systems shall be clearly marked with a permanent, legible warning notice indicating that the disconnection of the grounded conductor(s) may result in overvoltage on the equipment. NEC 690.5(C) A label shall appear on the utility interactive inverter or be applied by the installer near the ground fault indicator at a visible location. NEC 690.52 AC modules shall be marked with identification terminals or leads with the ratings as shown on the label. NEC 690.53 A permanent label for the direct-current PV power source shall be provided by the installer at the PV disconnecting means. NEC 690.54 All interactive system points of interconnection with other sources shall be marked at an accessible location at the disconnecting means as the power source and with the rated AC output current and the nominal operating AC voltage. NEC 690.55 PV power systems employing energy storage shall also be marked with the maximum operating voltage, including any equalization voltage and polarity of the grounded circuit conductor. NEC 690.56(C) Each Rapid Shutdown Switch shall be permanently marked to identify it as a Photovoltaic Rapid Shutdown. The sign or placard shall be marked as "PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN" using white letters that are 3/8" tall on a red background and shall be reflective. NEC 690.64 Points of connection shall be in accordance with NEC 705.12. Adhesive Fastened Signs ANSI Z535.4 – 2011 Product Safety Signs and Labels, provides guidelines for the design and durability of safety signs and labels for application to electrical equipment. NEC 110.21(B)(1) The label shall be suitable for the environment where it is installed. NEC 110.21(B)(3) Where required elsewhere in this code, all field applied labels, warnings and markings should comply with ANSI Z535.4. NEC 110.21(B) FIELD MARKING Adhesive fastened signs may be acceptable if properly adhered. Vinyl signs shall be weather resistant. IFC 605.11.1.3 NEC 690.17(E) l Part No. 596-00497 NEC 690.35(F) l Part No. 596-00588 NEC 690.15 & NEC 690.13(B) l Part No. 596-00613 NEC 705.12(D)(3) & NEC 690.64 l Part No. 596-00495 WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM NEC 690.54 l Part No. 596-00239 PHOTOVOLTAIC AC DISCONNECT MAXIMUM AC OPERATING CURRENT: MAXIMUM AC OPERATING VOLTAGE: NEC 110.27(C) and OSHA 1910.145(f)(7) Part No. 596-00499 NEC 705.12(D)(3-4) & NEC 690.64 Part No. 596-00587 NEC 690.10(C) l Part No. 596-00591 NEC 690.15 & NEC 690.13(B) l Part No. 596-00243 NEC 690.15 & NEC 690.13(B) l Part No. 596-00243 NEC 705.12(D)(2)(3b) l Part No. 596-00589 NEC 705.12(D)(2)(3b) Where two sources, one a utility and the other an inverter, are located at opposite ends of a busbar that contains loads, a permanent warning label shall be applied to the distribution equipment adjacent to the back-fed breaker from the inverter that displays the text on Part No. 596-00589, or equivalent wording. NEC 705.12(D)(3-4) Equipment containing overcurrent devices in circuits supplying power to a busbar or conductor supplied from multiple sources shall be marked to indicate the presence of all sources. NFPA 2012 130.5(C) Same as NEC110.16 but includes additional label information that was required after 9/30/2011. Check latest 2012 NFPA Arc Flash requirements. OSHA 1910.145(f)(7) Warning tags are used to represent a hazard level between "Caution" and "Danger." 33

Articles in this issue

Links on this page

view archives of Solar Advantage - LITPD264 Rev6