Machinery Lubrication magazine published by Noria Corporation
Issue link: https://www.e-digitaleditions.com/i/1032074
24 | September - October 2018 | www . machinerylubrication.com HYDRAULICS never put it under load until the temperature is at least 70 degrees. Pump output is directly proportional to drive motor speed. If the drive motor is replaced with one that exceeds the pump's specifications, it will cavitate and destroy itself rapidly. Aeration results from outside air entering the pump suction. A leak in the suction line, a worn shaft seal or misaligned couplings can all cause a pump to aerate. Remember that the pressure in the pump suction is below atmospheric pressure, so oil won't leak out, but air will leak in. A low fluid level can result in air being drawn into the pump along with the oil, so check your fluid levels. A few years ago, I was called into a plant that had foam oozing out of a breather 30 minutes after start-up. e eventual cause was a bad coupling that wore the pump's shaft seal. Air entered the system through the shaft seal, which eventually returned to the reservoir and purged out through the breather. Overheating Excessive heat is the second most common cause of hydraulic failures, with the first being contaminated oil. As long as the machine is still making money, most people will allow a heat problem to continue. But if left unchecked, an overheating machine will always result in downtime. Mineral oil begins to chemi- cally break down at 140 degrees F. Varnish deposits develop and cause valves to stick. Viscosity drops, and the oil's lubricating properties begin to diminish. Every compo- nent in the machine suffers as a result. I recently was called into a plywood plant for a system that was shutting down due to a high oil temperature. e system used a 60-gallon-per-minute, variable-displacement vane pump to drive a hydraulic motor. e oil that flowed out of the hydraulic motor was ported through a heat exchanger before returning to the tank. e system ran fine as long as the hydraulic motor was rotating, but a shutdown occurred during long idle periods. A flow meter was installed to check the case drain flow. When operating, the pressure to drive the motor was 350 PSI, and the case flow was 3 GPM. When the system was idle, the pressure built to 900 PSI at the pump outlet port. e case flow then increased to 9 GPM. e case drain line was ported directly to the reservoir, preventing any cooling of the oil. e pump was excessively bypassing at 900 PSI, gener- ating excessive heat. I am always amazed that people often deal with a heat problem by adding a heat exchanger or increasing the size of the one already in place. is doesn't solve the problem but only masks the symptom. When a machine is overheating, it is working harder than necessary. Money is wasted by allowing the machine to over- heat, and then more is wasted to cool it back down. Keep in mind that if the machine was operating fine two weeks ago and now is overheating, the problem is not a design issue. Something is wrong, and it needs to be addressed. Increasing the capacity of the heat exchanger (or laying bags of ice on the machine, soaking it with a fire hose, opening the doors, etc.) is not the answer. Find the source of the excess heat and correct it. ere are hundreds of possible heat sources in most hydraulic machines, but a few are most common. Incorrect pressure settings cause a lot of heat problems. If a pump compensator is set higher than the relief valve, temperatures will soar. In the absence of designer recommendations, I recommend the relief valve be set 250 PSI higher than the compensator. If the relief valve is dumping, it always needs to be investigated. Remember that relief valves in pressure-compensating pump systems only dump when something is wrong. Pressures generally are set higher than they should be. is can be a problem with servo and proportional valve systems. Servo and proportional valves are notorious heat generators because they are seldom, if ever, all the way open. ere is always a pressure drop across them. Whenever a pressure drop occurs and no useful work is done as a result, there will be heat. e higher the pressure in the system, the greater the pressure drop across the valves and the more heat is generated. Even if all your pressures are set correctly, the machine can overheat if it has a heat exchanger that is not properly cared for. Air heat exchangers, which are similar to a car's radiator, should be located near a cool air source. e fins must also remain clean, i.e., you should always be able to see daylight through them. If the fins become bent, they must be straightened with a metal comb. Sludge in a reservoir will absorb heat and make it difficult for the reservoir to dissipate it. Sludge can also enter the pump's suction line and contaminate the entire system. Drain and clean the reservoir at least once a year or more frequently in dusty environments. One of the best proactive measures you can take is to develop a preventive mainte- nance checklist for each of your hydraulic systems. By checking your systems on a regular basis, you'll often find a failing component before it causes a shutdown of the machine. ML About the Author Jack Weeks is a hydraulic instructor and consultant for GPM Hydraulic Consulting. Since 1997, he has trained thousands of electricians and mechanics in hydraulic troubleshooting methods. Jack has also taught radio-wave propagation for the U.S. Air Force and telecommuni- cations equipment operation and repair for the Central Intelligence Agency at American embassies overseas. Sludge in a reservoir absorbs heat, which can be difficult to dissipate.

