32 March 2019 Tablets & Capsules ering. Does disassembly and reassembly require special tools and procedures? Layout. Consider your required layout and determine how the machine will connect to upstream and down- stream equipment and how you will make and break con- nections when disassembling and cleaning the machine. These connections may be split butterfly valves, other containment-type valves, or continuous liner systems, each of which require vertical height that you must account for in the layout. The connections for the press, tablet chute from press to deduster, deduster, metal detector, and tablet collection container must all be WIP or CIP to ensure that no dust escapes from the system. Water control and usage. Determine where the water will go during the WIP or CIP process. Water usage can also be a factor because you must collect some hazardous material and dispose of it at a hazardous-waste collection facility. By minimizing water usage, you can keep dis- posal costs to a minimum over a machine's life. If clean- ing off-line, you must also determine how you will dis- connect the deduster from the upstream and downstream equipment in a contained method. Dust collection. Removing the dust consistently from a deduster, with no fluctuations in volume and vacuum pressure throughout a batch, is necessary for proper sys- tem performance. Determine how dust collection makeup air will enter the deduster and what happens if an upset • How will we manage the dust collection makeup air? • How will we handle an equipment malfunction? • Will the process need metal detection? • Will we need a diverter for multiple collection containers? Normal production requirements. Identify your needs related to capacity and dedusting efficiency as well as the physical arrangements you require in a typical deduster. These include tablet size and shape, rate produced by the press, tablet press outlet height, and tablet collection container height. Hazardous products. Product and powder hazards are broken down into five bands, OEB 1 through 5, with 1 being the highest level of allowed exposure and 5 being the lowest. These bands correspond to OEL levels. The OEL levels are measured in micrograms per cubic meter (mcg/m3), with 100-1,000 mcg/m3 being OEB 1 and <0.1 mcg/m3 being OEB 5. Validate the dust tightness of a WIP or CIP machine using the Standardized Measurement of Equipment Particulate Airborne Concentration (SMEPAC) guideline. SMEPAC is a guideline sponsored by the International Society of Pharmaceutical Engineers (ISPE) that gives performance testing criteria to allow you to accurately compare machines. Assembly and disassembly. Evaluate the ease of assembly and disassembly of the dedusters you're consid- Sign up now by emailing kmyers@cscpub.com your name, company, and email address. To see a sample, please visit our website. www.tabletscapsules.com