Issue link: https://www.e-digitaleditions.com/i/623533
Progressive Design, Progressive Manufacturing, Progressive Products 1-888-235-1732 • 304SS, 316SS or CS Construction • Easy Change, Maintenance Free Seals • Premium L10 Life Ouboard Bearings • Factory Assembled Air Purge Included • 12"x12" & 24"x24" Sizes Available Made in America Made in America Quality is the Difference Lumpbreakers www.progressiveproductsinc.com i d t i 85 PBE January 2016 or interferences) to immediately direct a pressure buildup outside the building through an adjacent wall or roof. Rooftop vents may have a hinged cover that opens or releases during an explosion. Check the cover hinges to be sure they'll open when needed. Tie loose-fitting covers to a lanyard or chain anchored to the roof to prevent them from becoming projectiles during an explosion. The vent exterior may have a thin plastic membrane or weather barrier to keep moisture, dust, insects and other contaminants from entering the duct and interfering with the explosion panel's operation. This membrane should be sufficiently thin to break apart easily without creating significant backpressure when a dust explosion occurs. The vent cover should be lightweight and designed to rupture or open during a deflagration. The vent cover shouldn't be snug fitting and should be wider than the vent duct. The cover's fasteners should be strong enough to secure the cover but fragile enough to release the cover in the event of an explosion. Light gauge nylon fasteners work well, for example, but you should never use metal bolts. Despite efforts to protect the duct from weather or outside conditions, a vent cover or membrane can still fail or be breached. Water or snow can get inside a vertical vent and rest on the rupture panel or build up in the duct, for example. This can affect the vent's burst pressure and effectiveness. Insect activity around a vent connected to a sugar or sweetener operation may be an indication that the vent's explosion disc has been compromised. Regularly check the exterior area around explosion vents on rooftops or exterior walls to ensure that there are no obstructions, that the area is safe for venting, and that the vent hasn't been compromised in any way. If your indoor dust collector isn't located near a wall or roof for direct venting outside, you can install an indoor (or flameless) explosion vent. Indoor explosion vents use a This dust-collector tubesheet is leaking, allowing dust to pass from the dirty side below the tubesheet to the clean side above.

