Powder and Bulk Engineering

PBE0116

Issue link: https://www.e-digitaleditions.com/i/623533

Contents of this Issue

Navigation

Page 69 of 125

1.800.527.2116 www.sssdynamics.com Call us, tell us what keeps you up at night. No room for multiple screens. Limited Space. Your bottom line matters to us. Think about the High Capacity Texas Shaker Screener. We are. Are you thinking that increasing your capacity increases your footprint? 68 PBE January 2016 triggers an alarm signal to alert operators of the problem and possibly shut down the process. To make the system fail-safe, a resistor is typically wired between the housing and rotor to complete the circuit. While the valve is operating, electrical current flows through the circuit, and the controller reads the resistor's value as a normal condition. If rotor contact occurs, the current bypasses the resistor through the contact point, triggering an alarm signal, but if a wire breaks or some other problem causes an open in the circuit (meaning the electrical resistance becomes infinite), the current stops flowing, triggering a fault signal. This prevents the system from operating if a wire is damaged or if a connector is un- plugged. How to make a spinning rotor part of an electrical circuit One of the biggest challenges of producing a properly functioning system, and where manufacturers spend the most development and manufacturing resources, is maintaining reliable electrical continuity between the detection circuit and the spinning rotor shaft. One method is to use a slip-ring assembly. Slip-ring technology is a well-proven, reliable method for maintaining excellent electrical contact with little to no electrical "noise" (or fluctuations in resistance). Devices that use slip-ring technology tend to be expensive, however, making the cost of some of these systems high. The other method used to make electrical contact with the spinning rotor shaft is to use a carbon copper brush, similar to the brush used on the motor in an electric drill or reciprocating saw. This method is inexpensive and good for conducting electrical current but can be sensitive to heat and contamination, which can cause resistance between the rotor shaft and the brush, interfering with the system's operation. System controls The control module for a rotor contact detection system is, in essence, an ohmmeter with alarm outputs and other adjustable settings. With limited exceptions, what you'll get is a 24-volt DC control module and possibly some connecting cables. You mount the module inside an appropriate panel for your application and wire the detection circuit to the valve and the alarm circuit to your plant's PLC. The module will send out an alarm to the PLC in the event of rotor contact or circuit fault. Some modules come with software that can be used to adjust settings and track alarm history. Most systems use simple open or closed switches on the control module for the rotor contact and circuit fault alarms. Some have separate switches for each condition, while others tie both conditions into one output. For troubleshooting, having separate rotor-contact and circuit- fault outputs is helpful.

Articles in this issue

Links on this page

view archives of Powder and Bulk Engineering - PBE0116