Issue link: https://www.e-digitaleditions.com/i/623533
1-888-235-1732 ROGRESSIVE P R O D U C T S I N C . The Elbow People™ www.progressiveproductsinc.com Made in America The Ceram-Back ® Blind Tee The mechanical protection of an impact elbow with all the protection of a Ceram- Back ® elbow. Abrasion has just met its match. One of many reasons to give us a call today. Better Solutions Around the Bend. 70 PBE January 2016 Some controllers also have a contamination alarm for when the controller reads a low circuit resistance but the measurement isn't low enough to indicate metal contact. Depending on your application, you can set up the system to simply notify operators of an issue, shut down the rotary valve, or even shut down the entire process in the event of a rotor contact. In any case, the system should be set up to prevent the valve from starting up if an alarm condition is present. Rotor contact detection system limitations A rotary valve rotor contact detection system won't solve all of your rotary valve damage problems. It can only alert you to metal contact between the rotor and housing and prevent further damage (if you use the alarm to shut down the valve). The system can't prevent what caused the metal contact in the first place. If you currently have problems with valves becoming damaged by improper handling and assembly, adding one of these systems will likely increase downtime and maintenance work unless you ensure that operators and maintenance staff are well trained on both basic rotary valve and rotor contact detection system operation. If you're retrofitting a rotor contact detection system to an existing rotary valve, the valve must be 100 percent damage-free when you install the system. You'll likely need to have a used valve rebuilt before you can add rotor contact detection. Also, this system doesn't turn your rotary valve into a metal detector. If metal from upstream processing equipment passes through the rotary valve without bridging the rotor and housing, no alarm will occur. A metal detector downstream from the rotary valve is still necessary to ensure that no metal contaminates your material. Another limitation of some rotor contact detection systems is that they won't function properly with materials that have some level of electrical conductivity. Materials such as clean-in-place fluids, wet materials, or even powders with high moisture content can cause false contact alarms. Some systems have adjustable settings to compensate for these types of materials, but others don't. If your valve will be handling a conductive material, make sure you select a detection system designed for such a material. Common problems associated with rotor contact detection systems Troubleshooting metal contact alarms can be one of the most frustrating endeavors that any maintenance technician has to deal with. Sometimes the area of contact inside the valve is so small that you can barely see the spots on the housing and rotor that are making contact. Fixing this type of contact can take multiple repair, reassembly, and testing attempts to resolve. A larger rotor-

