72 PBE January 2016 housing contact may require that parts be completely resurfaced to remove the damage. Both problems can lead to extended downtime, but, remember, this is all in an effort to avoid catastrophic valve failure, material contamination and damage to downstream equipment. While these systems are all self-monitoring, a skilled electrical technician familiar with the rotor contact detection system may need to diagnose any electrical problems that arise. Detection system suppliers have generally been slow to provide helpful troubleshooting solutions with their systems. Some suppliers provide software programs enabling you to use a laptop or human- machine interface (HMI) to view troubleshooting screens that show real-time resistance values and allow you to turn alarm outputs off during system maintenance. A local resistance readout at the valve is the best troubleshooting aid, but this requires the technician to carry a laptop and the control module to be mounted close to the valve. Having the control module in a panel farther away, or having a central HMI display of software only, limits the software's ability to help when troubleshooting contact and circuit issues. For assistance selecting a rotary valve that includes rotor contact detection, a supplier with installation and field service experience with various systems on the market is your best resource. PBE Find more information on this topic in articles listed under "Valves" in Powder and Bulk Engineering's article index in the December 2015 issue or the Article Archive on PBE's website, www.powderbulk.com. (All articles listed in the archive are available for free download to registered users.) Scott Lodermeier handles component sales and project m a n a g e m e n t a t P o w d e r P r o c e s s - S o l u t i o n s (slodermeier@powder-solutions.com). He holds an AAS d e g re e i n e n g i n e e r i n g d r a f t i n g a n d d e s i g n f ro m Dunwoody College of Technology in Minneapolis and has 14 years experience in rotary valve sales, engineering, and technical support in the dairy and food processing industries. Powder Process-Solutions Chanhassen, MN 877-236-3539 www.powder-solutions.com

Articles in this issue

Links on this page

view archives of Powder and Bulk Engineering - PBE0116