24 May 2015 Tablets & Capsules time distributions, PAT, and process control. He noted that some aspects of the system would require optimiza- tion before it could be used for production, but it satis- fied long-term operational requirements under the condi- tions tested. The system is designed to produce 50 kilograms per hour, and that is where results were best. At 90 kilograms per hour, the RSD variation of tablet weight was 5 percent. "When pushed to the extremes of opera- tion, all operating conditions resulted in acceptable tablets for all three formulations," Meyer said. Daniel Blackwood of Pfizer provided more details about the company's integrated PCMM system, which uses a pod to house all the process equipment and control systems necessary to continuously manufacture tablets from direct-compression blends or wet granulations. The modules can be deployed worldwide, allow- ing the company to begin manufacturing quickly and at lower cost compared to establishing a traditional facility, especially in emerging-market regions. The week before the conference, Pfizer had "brought to life" six modules of the pod at its Groton, CT, site. (The com- pany uses POD enclosures supplied by G-Con Manufacturing of College Station, TX.) Blackwood emphasized the importance of gravimetric feeders and blenders in developing a continuous manu- facturing system. He said that continuous powder mixers should be installed as close as possible to the tablet press. He described a prototype vertical mixer made in-house a few years ago that sits inside the tablet press enclosure. The mixer's design has since been commercialized as part of the PCCM program. After his prepared remarks, Blackwood responded to a question about variable mate- rials by saying there is an "untapped opportunity for NIR probes, which can be used for more than just potency signals." One example is to check whether other quality attributes, such as those of excipients, are at the high or low end of specification, he said. Jeff Katstra of Vertex discussed how his company developed and implemented a continuous manufacturing system simultaneously with its development of a new drug product to treat cystic fibrosis. He said continuous manufacturing streamlines QbD development and NDA submission. And while there is a presumption of regula- tory difficulty, authorities encourage new technology. Breakthrough therapies offer a good opportunity for companies to work closely with the US regulators. The project began with using individual unit opera- tions in the development and manufacture of clinical for- mulations in discontinuous mode. Next, Vertex installed a GEA ConsiGma-25 and qualified it for "continuous clini- cal batch manufacture." The final step was the creation of its development and launch rig that can use multiple pro- cessing technologies. The rig, installed at a CDMO in the UK [2], is equipped with PAT devices for process monitoring and control and real-time release. It also has two segregation points, one after milling and another after compression. He said it takes 2 or 3 days to do a major cleaning. The bottleneck is usually the sink, and the company is seeking to add washroom capacity. The company also operates a continuous manufacturing sys- tem in Boston. Philippe Cappuyns, a research fellow at Johnson & Johnson, London, UK, addressed switching legacy prod- ucts from batch to continuous manufacturing. He pre- sented a case study in which an existing product made using a conventional fluid-bed granulation-dryer was moved to a continuous process using GEA's ConsiGma- 25. The study compared granule and tablet properties and tested the stability and repeatability by performing three consecutive produc- tion runs. It also monitored process outcomes and gran- ule and tablet properties as a function of process time. The project required 6 to 8 weeks of work at GEA to develop a process worthy of in-depth assessment and 2 years of further study. The company has introduced continuous direct compression at a site in Puerto Rico and is in the midst of launching continuous wet granulation at a site in Italy. He stressed the importance of selecting the right type of mill screen in order to obtain the desired particle size distribution and to avoid overheating. He also said it's important to run long trials for issues to become visible. Xiaoyu Zhan, a senior research scientist at Eli Lilly in Indianapolis, IN, discussed her team's experience using PAT tools to monitor and control continuous manufactur- ing processes. She said continuous processing changed how her company develops products and requires more and earlier collaboration among formulators, analytical experts, and data managers. Her team conducted an 11- run DoE to optimize drug load and process parameters in 2.5 hours using just 2 kilograms of API. The same effort using a batch approach would have taken 3 weeks and required making three to four batches per week. She described in detail how her team designed and built a system that automatically samples and analyzes individual tablets using NIR. Standard tablet shapes are analyzed in 15 to 45 seconds; complex shapes can require 1.5 to 3 minutes. Marianthi Ierapetritou is a professor and chair of the Department of Chemical and Biochemical Engineering at Rutgers University. The title of her talk was "Taking con- tinuous processing from good to great: The application of advanced process controls and real-time analytics." Topics included flowsheet modeling, design space evalua- tion, process flexibility, and feasibility. It is important to know how much uncertainty a process can tolerate and how to assess the effect of uncertainty, she said. She also discussed integrating a material properties database and how to reuse accumulated information to better under- The FDA is encouraging manufacturers to adopt continuous manufacturing, which can streamline QbD development and NDA submission.