Issue link: https://www.e-digitaleditions.com/i/807837
Setting up a film coating process While Figure 2 shows a great number of relevant para- meters, only a handful of them can be used to optimize a coating process. Parameters such as tablet size, shape, and mass, as well as target weight gain, are usually fixed. The concentration of the coating suspension can be opti- mized within certain limits, as discussed above, but it can hardly be changed while the coating process is underway. The parameters that can be adjusted during a coating run include: •The inlet-air temperature and volume and the spray rate (drying conditions) •The atomizing-air pressure (atomization), and •The drum speed (blending). Drying conditions. The first step is to identify the combination of inlet-air temperature, air volume, and spray rate that will achieve the target bed temperature. In the case of a standard HPMC-based coating, for example, the ideal bed temperature is between 38° and 42°C. Again, you must determine the actual delivery rate of the coating suspension at the intended pump setting(s) and for the selected spray nozzle(s). Next, identify the corre- lation between the actual pump rate, the inlet-air temper- ature, and the resulting bed temperature. While this analysis must be conducted for each piece of coating equipment, it is usually sufficient to do it for only one (i.e., the standard) inlet-air volume. Increasing the inlet- air volume almost immediately increases drying capacity, but it is prudent to reserve some capacity so you can address over-wetting emergencies. Thus, coaters should only be run at about 80 percent of their maximum air vol- ume under standard coating conditions. Figure 3 shows the correlation of outlet-air temperature, spray rate, and inlet-air temperature. Atomization. Once the spray rate is set, adjust the atom- izing-air pressure to achieve an appropriate droplet size dis- tribution. As a general rule, the higher the viscosity and/or spray rate, the higher the atomization pressure must be. Ideally, you would measure the actual droplet sizes in the spray plume, but that is usually not possible. Instead, the common procedure is to slide a sheet of paper (sup- ported by a ruler or spatula) through the spray zone and 16 April 2017 Tablets & Capsules Figure 3 Correlation of outlet-air temperature, spray rate, and inlet-air temperature Outlet-air temperature (˚C) Spray rate (g/min) 70˚C inlet air 50˚C inlet air 60˚C inlet air 80˚C inlet air Dew point 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 70 60 50 40 30 20 10 0 Duration Tablet shape Smoothness Even and smooth coating Pan speed Film thickness Uniformity Concentration Atomizing air Drying capacity Viscosity Spray rate Figure 2 A map of coating parameters showing their interdependence Bed temperature Bed relative humidity Outlet temperature Outlet dew point Weight gain Droplet size Inlet temperature Heat loss Inlet volume Inlet dew point Increasing the inlet-air volume increases drying capacity. Reserve some capacity so you can address over-wetting emergencies.