Tablets & Capsules January 2019 21
Figure 3
Correlation between degradant levels and dissolution
release rate during storage at accelerated conditions
Initial 1 month 2 months 3 months
Storage time
Degradant 1 Degradant 2 Capsule dissolution
Percentage
of
capsule
dissolved
at
45
minutes
dissolution
time
120
100
80
60
40
20
0.5
Percentage
of
degradant
(area
under
curve)
4
3.5
3
2.5
2
1.5
1
0.5
0
mixed the vial, and allowed the mixture to stand for
approximately five minutes.
The scientists then added 1.0 milliliter of acetoni-
trile and 16.0 milliliters of high purity water. The vial
was mixed well and allowed to equilibrate to room
temperature to derivatize. They prepared a formalde-
hyde standard at a concentration of 4 µg/mL and ana-
lyzed both the standard and the samples using the
same HPLC finish described earlier.
The derivatization results showed a significant
increase in formaldehyde concentration compared to
the control sample, which confirms the generation of
formaldehyde during degradation.