With this degradation pathway confirmed, the scien-
tists recommended that the formulation be changed from
gelatin capsules to hydroxypropyl methyl cellulose
(HPMC) capsules to avoid the crosslinking problem. T&C
References
1. https://www.thermofisher.com/us/en/home/life-
science/protein-biology/protein-biology-learning-center/
protein-biology-resource-library/pierce-protein-methods/
chemistry-crosslinking.html.
2. Thermo Fisher Scientific. "Thermo Scientific
Crosslinking Technical Handbook." Life Science Research.
2012. http://tools.thermofisher.com/content/sfs/bro
chures/1602163-Crosslinking-Reagents-Handbook.pdf.
3. Bernard Testa and Joachim M. Mayer. "The
hydrolysis of carboxylic acid ester prodrugs." Hydrolysis
in Drug and Prodrug Metabolism: Chemistry, Biochemistry, and
Enzymology. Chapter 8. Verlag Helvetica Chimica Acta.
2003. pages 501-503.
4. G. A. Digenis, T. B. Gold, and V. P. Shah. "Cross-
linking of gelatin capsules and its relevance to their in
vitro-in vivo performance." Journal of Pharmaceutical Sciences.
1994. Vol. 83, No. 7. pages 915-921.
Jerry Mizell is director of analytical services, Steven Genovese is
an analytical chemist II, and Jerry Neal is an analytical chemist
III at Metrics Contract Services, a full-service global contract
development and manufacturing organization specializing in
oral dosage forms.
Figure 4 shows an overlay chromatogram for stan-
dard and sample preparations unstressed and stressed.
Conclusion
As the stress studies showed, degradation of the API
liberated formaldehyde, which caused crosslinking
between the API and the gelatin capsules in the stressed
samples in the drug product stability study.
Figure 4
Overlay chromatogram for standard and sample
preparations unstressed and stressed
Absorbance
units
0.080
0.070
0.060
0.050
0.040
0.030
0.020
0.010
0.000
-0.010
0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00
Minutes
Formaldehyde
Standard
Stressed sample
Unstressed sample
Blank
22 January 2019 Tablets & Capsules
The
solution to your
Solid Dosage
needs
Specialty Measurements Inc.
Website: www.smitmc.com
Phone: +1 (908) 534-1500
R&D to Pilot Scale Production
Monolayer & Bilayer
Tablet Presses
Advanced Data Acquisition &
Analysis System
Excellence in Quality & Service
Visit us at Booth 3341
Interphex
April 2-4, 2019
Jacob Javits Convention Center
New York City, NY